MAX. CAPACITIES FROM 10 TO 200 kg. Minimum load cell verification interval Vmin = EMax / 10,000–15,000, maximum number of verification intervals nLC = 3000, sensitivity 2 mV/V ±10%, temperature effect on zero of ±0.0140% F.S./10K for 10 kg, ±0.0093% F.S./10K for 15 kg, ±0.0140% F.S./10K for 20 kg, ±0.0093% F.S./10K for 30 kg, ±0.0140% F.S./10K for 50 kg, ±0.0140% F.S./10K for 100 kg, and ±0.0140% F.S./10K for 200 kg, temperature effect on full span of 0.0058% F.S./10K in the −10°C/+20°C range and 0.0087% F.S./10K in the +20°C/+40°C range, compensated temperature range −10°C/+40°C, operating temperature range −10°C/+50°C, maximum excitation voltage without damage 15 Vdc, input resistance 300–500 Ohm, output resistance 300–500 Ohm, zero balance 0 ±0.12 mV/V (at 100 V), insulation resistance greater than 2000 MOhm, mechanical limit load in service 150% F.S., destructive load 300% F.S., deflection at nominal load less than 0.5 mm, and supplied with a 6-wire shielded cable 3 m long and 4.7 mm in diameter.